In one line: once line of sight fails, wires carry the signal — but every circuit needs a way back, and long wires fight you with resistance.

Companion to: Charles Petzold, Code (2nd edition), chapter 5.


Wiring a signal between two places

Problem Solution
Every circuit needs a return path Run a second wire back
Two-way signalling doubles the wiring Share one common return wire between both circuits
Even the common wire costs money over miles Use the earth itself as the return (a ground connection at each end)
Long wires have resistance, so the bulb dims Use thicker wire, a higher voltage, or regenerate the signal (next chapter)
  • Resistance grows with length and falls with thickness.
  • Wire gauge (AWG): a lower number means thicker wire. Cat6 cable is typically 23 AWG, Cat5e 24 AWG.

Key terms

Term Meaning
Common A shared connection that several circuits use as their return
Ground / earth A reference point at 0 V; historically the literal earth
Voltage drop Voltage lost along a wire because of its resistance
Attenuation A signal weakening over distance

🔐 Security and IT connections

  • Distance limits come from this chapter. Copper Ethernet tops out at 100 m because of attenuation. Beyond that you need a switch (which regenerates the signal) or fibre.
  • PoE loses power over long runs. That’s why PoE budgets assume some voltage drop along the cable.
  • Grounding is safety. The earth pin on a plug gives fault current a safe path. ESD straps clip to ground for the same reason.
  • Serial links share a signal ground (RS-232 console cables to switches and routers): without a common reference, a “1” can’t be told from a “0”.

Practice drills

1. Two friends each want to signal the other. Why does a shared common wire save cabling?

Both circuits can use one return wire, so you need three wires instead of four.

2. A 130 m Ethernet run is flaky. Why, and what fixes it?

It exceeds the 100 m copper limit and the signal attenuates. Add a switch midway, or use fibre.

3. Which is thicker: 22 AWG or 26 AWG?

22 AWG — a lower gauge number means thicker wire.


Key takeaways

  • Every circuit needs a return path; a shared common or earth ground saves wire.
  • Resistance grows with wire length, causing voltage drop and signal loss.
  • Distance limits, grounding and signal regeneration in networking all trace back here.